Intel® Fortran Compiler 16.0 User and Reference Guide
Portability Subroutine: Flushes and closes I/O buffers, and terminates program execution.
USE IFPORT
CALL ABORT[string]
string |
(Input; optional) Character*(*). Allows you to specify an abort message at program termination. When ABORT is called, "abort:" is written to external unit 0, followed by string. If omitted, the default message written to external unit 0 is "abort: Fortran Abort Called." |
This subroutine causes the program to terminate and an exit code value of 134 is returned to the program that launched it.
USE IFPORT !The following prints "abort: Fortran Abort Called" CALL ABORT !The following prints "abort: Out of here!" Call ABORT ("Out of here!")